Reference
The six cases
Three real problems and three traps. Every scene in the drill holds exactly one of them. The pictures here are examples drawn by the same code, with the answer outlined.
Missing or settled insulation
- Looks like
- A block of different temperature filling one bay between studs or joists: cooler from inside in winter. Loose fill slumps over the years, so the upper part of the cavity can be bare, with a level line where the fill now ends.
- Gives it away
- Straight sides that stop at the framing. The studs or joists hold the edges, so the pattern is as tidy as the framing is.
- Looks similar
- An air leak (ragged, streaky, crosses the framing), a cold ceiling corner (a smooth fade along the edge, in every bay).
- Confirm it
- The pattern only shows when there is a steady temperature difference across the wall. Scan the same bay from outside before sunrise on a cold day (it should read warm there), or check a ceiling from the attic. An insulation contractor or energy auditor can confirm what is in the cavity.
Air leak
- Looks like
- Fingers or streaks spreading from a crack, a joint, an outlet, a hatch or a corner. Inside in winter they are cool; outside, warm air escaping paints warm streaks.
- Gives it away
- Feathered, ragged edges that fade with distance from the source and run across the framing as if it were not there.
- Looks similar
- Missing insulation (a tidy block between framing), moisture (a soft patch that does not start at a gap).
- Confirm it
- Leaks grow when air is pushed through the house: on a windy day, or with the house depressurised for a blower-door test, the streaks get longer.
Moisture (wet material)
- Looks like
- A cool, irregular area shaped like a stain, whose outline wanders instead of stopping at the framing. Look for it where water is used or gets in: plumbing runs, tub and shower surrounds, roof openings, window sills.
- Gives it away
- Evaporation draws heat out of damp material, so the wet area reads cooler than the dry surface around it. Its shape follows the water, not the studs or joists, and it stays put when you change your angle.
- Looks similar
- A reflection of something cold (it moves when you step aside), an air leak (starts at a gap and streaks).
- Confirm it
- A thermal image only suggests moisture. A moisture meter on the spot confirms it.
Sun loading
- Looks like
- Outside walls glowing warm, with a sharp line where a roof edge, a tree or a neighbouring house threw its shadow. It can last well after sunset.
- Gives it away
- The warm area matches what the sun could reach and stops at the shadow line. The scene card says when the sun was on the wall.
- Looks similar
- Warm air escaping (streaks from gaps at night), heat loss through the wall (only readable once the sun has been off the wall for hours).
- Confirm it
- Look again before sunrise, or scan from inside. Standard practice for building scans asks for no recent sun on the surface being read.
Reflection
- Looks like
- A warm or cool shape on a glossy surface (glazed tile, glass, polished metal): often you, a lamp behind you, or a cold window.
- Gives it away
- It moves when you step aside. Glossy surfaces reflect infrared the way a mirror reflects light; the shape belongs to the room, not the surface.
- Looks similar
- Moisture behind tile (stays put), a warm pipe in the wall (stays put).
- Confirm it
- Change your angle and watch. In the trainer, press Step aside.
Wrong emissivity
- Looks like
- Part of a hot pipe or duct reading far colder than the rest, with a perfectly sharp step where paint or insulation ends and bare metal begins.
- Gives it away
- Metal carries heat along its length too well for a real step like that. Bare, shiny metal has a low emissivity, so a camera set to 0.95 mostly sees the room reflected in it.
- Looks similar
- A cold spot or a blockage in a line (those fade gradually along the pipe, they do not step).
- Confirm it
- Read the painted run of the same pipe instead. Or, where the metal is safe to touch, give it a small matte patch with an emissivity near 0.95 and read the patch once it has warmed through.
Level and span, in one paragraph
A thermal camera turns temperatures into colours. The span is how many degrees the whole colour range covers, and the level is the temperature in its middle. Auto span stretches the colours from the coldest to the hottest thing in view, so one hot lamp or heat register can squash a 2-degree finding into a single colour. Narrow the span around the surface you care about and the finding appears; the picture's data never changed.
Sources
- ASTM C1060, Standard Practice for Thermographic Inspection of Insulation Installations in Envelope Cavities of Frame Buildings (ASTM International).
- ASTM E1186, Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Barrier Systems (ASTM International).
- ISO 6781-1:2023, Performance of buildings — Detection of heat, air and moisture irregularities in buildings by infrared methods — Part 1: General procedures.
- Emissivity of bare and painted metals: published emissivity tables, e.g. Incropera, DeWitt, Bergman and Lavine, Fundamentals of Heat and Mass Transfer, appendix table of total emissivities of selected surfaces.
These are summaries in our own words for practice, not the standards' text. Levelspan is not a course and does not teach to any certification.
On a real building, a thermal image is a starting point, not a diagnosis. Leave outlet covers, switch plates and electrical panels closed: never open them to get a better look. For anything electrical, roofing, plumbing, gas or structural, bring in a licensed electrician, roofer, plumber, gas fitter or structural engineer.